Product Description:
X431 Oscilloscope is designed to analyzes data for all kinds of the testing applications on the automotive parts (including circuits, sensors,actuators, ignition etc.). to resolve complex electrical faults.

O2-2 Scopebox: Advanced Scopebox For Solving Complex Electrical Faults
Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detects high level faults on various electrical components, such as sensors, acturators and circuits.
By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults that enable the shop and technician to enlarge their scan tool's functionality.
Function:
Provides all kinds of the testing applications on the automotive parts (including circuits, sensors, actuators, ignition etc.).
Menu Includes the following options:
Measure: It provides 23 parametric measurement items.
Save: It allows you to save the current waveform as a reference waveform for future comparison.
Display: Sets the display mode of the waveform.
UserSetting: The following items are available: storage depth, factory reset, self-adjust (self-calibration) and save & recovery.
About: Displays the detailed information of the app.

Features:
1. Features the ability to record and playback high-resolution waveform data for future analysis.
2.. One key enable function allows users to capture a particular waveform which makes the process 70% more efficient as compared to other scopes.
3. Access to 23 variants of automatic measurements that are displayed on one screen for an easy switch.
4. Ability to input names and characters directly by clicking on the virtual keyboard, this operation streamlines the process and contributes to 90% efficiency.
5. Use the zoom in/out feature to review precise details.
6. Customizable personal system settings that can be saved as configuration files for viewing.
7. The self-calibration function allows optimization of the oscilloscope signal path for maximum measurement accuracy.
8. Magnifies waveform math operations, such as addition, subtraction, multiplication and FFT function for high level waveform analysis.
9. Multiple automotive tests include circuits, sensors, actuators, ignition tests and more.
10. X431 Oscilloscope is designed to analyzes data for all kinds of the testing applications on the automotive parts (including circuits, sensors,actuators, ignition etc.). to resolve complex electrical faults.
11. Library of predetermined waveform signals, built-in memory; Choose of the waveform display speed for fast analysis.
12. Registration and storage of the tested signals for later analysis and troubleshooting.
13. Auto adjusting of all chart signals on all 4’s channels.
14. Separate grounding of each channel to minimize distortion of test signals.
15. High quality BNC connectors.
16. Complete set of adapters for ignition systems, sensors, connectors and other accessories.

O2-2 Scopebox Oscilloscope Advantages:
*Channels 4
*Bandwidth 100 mhz
*Rasing time less than 3.5 ns (typical)
*5 years W-arranty. 24 Hours NON STOP Hassle-Free Technic Support
*LAUANCH Electrical analyzer (oscilloscope) is stable, durable and portable.
*Features the ability to record and play back high-resolution waveform data for future analysis;
*By integrating with the X-431 series scan tools via O2-2 application, it delivers accurate and conclusive diagnostic faults
*LAUNCH O2-2 Scopebox can detects high level faults on various electrical components, such as sensors, acturators and circuits.
*On-click enable function allows users to capture a particular waveform making the process 70% more efficient compared to other oscilloscopes.

Specification:
Channels: 4
Bandwidth: 100MHz
Rising Time:3.5ns (typical)
Accuracy: ±3%
Input Impedance: 1M ±1.5%
Input Type: Single-ended, BNC Connector
Input Coupling:DC, AC
Overload Protection: ±200V on single input
Timebase Ranges:
1ns~1ks (1 Channel)
1ns~1ks (2 Channels)
1ns~1ks (4 Channels)
Vertical Resolution: 8bits
Buffer Memory: 10M (for 4 Channels)
Power Interface: USB port, DC IN port
Data Exchange Via: USB
Trigger Mode: Normal, Auto and Single SEQ
Advanced Triggers: Edge, Pulse width

Launch O2-2 works with:
1. X431 PAD V Elite, X431 PAD VII Elite,PAD III
2. DBScar VII Device
X431 device: X431 PRO ELITE,Pros V5.0 Pro3s+, Pro TT, Pro3 ACE, Pro Dyno, Pro3 APEX, Launch V 5.0, X431 V+, X431 Pad II AE, X431 Torque, X431 Turbo,X431 Throttle, etc.
IMMO Series: X431 IMMO Elite,X431 IMMO PLUS
Creader Series: CRP919X BT, CRP919E BT
*O2-2 scopebox cannot be used with X431 Pro5.

How to Connect the Cables?
Different application scenarios require different connection methods (no matter which application scenario, the following connections are required):
First, power the oscilloscope box through the double-clip power cable: Connect one end of the double-clip power cable to the power interface of the oscilloscope box, and the other end to the vehicle battery to draw power (red is connected to the positive pole, black is connected to the negative pole).
Note: * PADVII series tablets support USB power supply.
2. Connect the Type B terminal of the USB cable to the Type B interface of the oscilloscope, and connect the other end to the USB interface of the diagnostic device.